sunflagsteel logo

Sunflag Steel Strengthening Safety Through District-Level Mock Drill

Demonstrating its unwavering commitment to safety, Sunflag Steel successfully conducted a comprehensive District-Level Mock Drill at the Underground LPG Bullet Tanks facility in Bhandara. The exercise saw active participation and seamless coordination from key authorities, including NDRF teams, district administration, health departments, and emergency services, reflecting a unified approach to crisis management.

Focused on enhancing emergency preparedness and response efficiency, the drill helped strengthen inter-departmental coordination and awareness. Such initiatives ensure that every individual is equipped to act responsibly during critical situations, reinforcing Sunflag Steel’s belief that safety is not just a priority, but a core value in every operation.

Share this blog:

Facebook
WhatsApp
Email
LinkedIn

Latest blogs

Related Post

Wire Mesh vs Rebar

Wire Mesh vs Rebar

Often projects involve the usage of concrete to create long-lasting construction results. Whether you are building walls, roads or other structures like bridges, pathways etc.,…

ECT For Bars

Acceptance Criteria

Minimum defect depth and length (FBH)

  • 0.7 mm FBH from 15—60 mm dia
  • 1.2 mm FBH above 60 dia

 
Minimum defect depth and length (SDH)

  • 0.5 mm x 10 mm {from 15—120 mm dia)
  • 0.3 mm SDH sensitivity can deduced by
    extrapolation depending on material SNR.

Phased Array Auto Ultrasonic Testing Salient Features

Phased Array Technology

Phased Array testing is a specialized type of ultrasonic testing that uses sophisticated multi- element array transducers and powerful instrumentation/software to steer ultrasonic beams through the test piece and map returning echoes.

No rotating movement, only electronic scanning is done:

  • Depth focalization for bar volume inspection (LW)
  • Electronic steering for bar surface inspection (SW)

Quality Highlights:

Capacity — 15 to 120 mm dia. Full bar volume inspection

Sunflag R&D Lab Is Equipped With Following State Of The Art Equipment

  • Scanning Electron Microscope with Energy Dispersive X—Ray Spectroscope (SEM—EDS) of Make — JOEL
  • Immersion Ultrasonic Testing Facility of Make — Olympus / Blue Star
  • Optical Microscope with Automatic Multiaxis stage Movement and Image Analysis software
  • Micro—hardness tester
  • Ferritometer
  • NABL Certified Testing Lab
  • R & D Centre Recognised DSIR Government of India

Scanning Electron Microscope With Eds

  • Key Function

– Microstructure analysis
– Quantitative 8L qualitative Analysis of Inclusions

  • Failure Analysis
  • Fractography
  • Inclusion with quantitative elemental analysis

Salient Features

Dimension of samples that can be tested :

– Round Bars :

  • Size 15-120 mm die.
  • Length 800mm
  • Round Corner Square Bars:
  • Size 60420 mm

UST Prob: 10 MHz — 6mm As Per Sep 1927